Beth Sharkey, Sarat Pudi, Ian Wallace Moyer, Lihui Zhong, Bianka Prinz, Hemanta Baruah, Heather Lynaugh, Sampath Kumar, K. Dane Wittrup, Juergen H. Nett
mAbs 9, 257–268. DOI: 10.1080/19420862.2016.1267090
Overview
Monovalent bispecific antibodies (bsAbs) that bind two targets simultaneously have broad potential clinical value, but their manufacture is complicated by the need to correctly pair heavy and light chains. A common light chain (cLC) bispecific format avoids much of this problem because no additional modifications to the antibody are required. However, purifying the desired bsAb from the two parental monospecific antibodies remains challenging. Current methods using salt gradient ion exchange chromatography (IEX) are only effective when the parent antibodies have relatively large differences in isoelectric point (pI). This study introduces the use of linear pH gradients for high-resolution separation of cLC bsAbs.
Key hypotheses and objectives
Hypothesis: Previous work has shown that pH gradients achieve higher resolution separation than salt gradients for analytical characterization of monoclonal antibodies. This study proposed that the same principle would extend to preparative-scale purification, and that a linear pH gradient combined with IEX could resolve a cLC bsAb from its two parental homodimers even when their isoelectric points differ by very little, which salt gradients cannot reliably achieve.
The objectives of the study were to:
Approach and techniques
Seven cLC bsAbs with parent antibody pI differences ranging from 1.33 to 0.10 pH units were expressed and purified by Protein A chromatography. The resulting mixtures of bispecific and parental homodimer byproducts were then separated using linear pH gradient IEX (both cation and anion exchange) and compared against traditional salt gradient IEX. Heterodimer purity was confirmed by mass spectrometry after IdeS cleavage to remove any heterogeneity that could be introduced by Fc glycans. The method was also tested using IEX resins with larger bead sizes suitable for commercial-scale manufacturing.
Major findings and results
Implications for therapeutic antibody development
This purification method addresses a real bottleneck in bsAb manufacturing by enabling separation of near-identical parental and bispecific species without requiring additional protein engineering to increase the pI difference between the antibodies. Combining IEX with linear pH gradient elution has the potential to become a broadly useful purification and polishing method for bsAbs generally, beyond the cLC format specifically tested in this study.